Skip to content
  • Home
  • Walton's
    • Home
    • Seasonings
    • Casings
    • Packaging
    • Supplies
    • Equipment
    • Smoking/Grilling
    • Sales
    • Giveaways
  • About Us
  • Topics
    • Unread
    • Recent
    • Random
    • Popular Monthly
    • Popular All-Time
    • Unsolved
    • Solved
  • Events
  • FAQ
  • Conv Chart
    • Seasonings
    • Cures
    • Additives
Skins
  • Light
  • Brite
  • Cerulean
  • Cosmo
  • Flatly
  • Journal
  • Litera
  • Lumen
  • Lux
  • Materia
  • Minty
  • Morph
  • Pulse
  • Sandstone
  • Simplex
  • Sketchy
  • Spacelab
  • United
  • Yeti
  • Zephyr
  • Dark
  • Cyborg
  • Darkly
  • Quartz
  • Slate
  • Solar
  • Superhero
  • Vapor

  • Default (No Skin)
  • No Skin
  • Team Blue Skin
Collapse
Meatgistics - Walton's - Community
  1. Home
  2. Categories
  3. Community
  4. Meat Processing
  5. Home meat processing shop

Home meat processing shop

Scheduled Pinned Locked Moved Meat Processing
165 Posts 26 Posters 13.9k Views 21 Watching
  • Oldest to Newest
  • Newest to Oldest
  • Most Votes
Reply
  • Reply as topic
Log in to reply
This topic has been deleted. Only users with topic management privileges can see it.
  • DeepwoodsbutcherD Deepwoodsbutcher

    Denny O it’s nrp. It’s still USDA certified and was considerably cheaper then frp. I decided this was an area I could go with the money saving option.

    Denny OD Offline
    Denny OD Offline
    Denny O
    Power User Cast Iron Canning Green Mountain Grill
    wrote on last edited by
    #121

    Deepwoodsbutcher What does “NRP” stand for? “____Reinforsed Panels”

    Denny O’s-Smokey Bones
    I’d rather be sit’in in a boat and thinking about God,
    Than sit’n in church and thinking about fish’in!

    DeepwoodsbutcherD 1 Reply Last reply
    0
    • Denny OD Denny O

      Deepwoodsbutcher What does “NRP” stand for? “____Reinforsed Panels”

      DeepwoodsbutcherD Offline
      DeepwoodsbutcherD Offline
      Deepwoodsbutcher
      Power User Veteran Regular Contributors
      wrote on last edited by
      #122

      Denny O Non-fiberglass Reinforced Plastic

      Denny OD 1 Reply Last reply
      0
      • DeepwoodsbutcherD Deepwoodsbutcher

        Denny O Non-fiberglass Reinforced Plastic

        Denny OD Offline
        Denny OD Offline
        Denny O
        Power User Cast Iron Canning Green Mountain Grill
        wrote on last edited by
        #123

        Deepwoodsbutcher said in Home meat processing shop:

        Denny O Non-fiberglass Reinforced Plastic

        So then, what exactly are they?

        Denny O’s-Smokey Bones
        I’d rather be sit’in in a boat and thinking about God,
        Than sit’n in church and thinking about fish’in!

        DeepwoodsbutcherD 1 Reply Last reply
        0
        • Denny OD Denny O

          Deepwoodsbutcher said in Home meat processing shop:

          Denny O Non-fiberglass Reinforced Plastic

          So then, what exactly are they?

          DeepwoodsbutcherD Offline
          DeepwoodsbutcherD Offline
          Deepwoodsbutcher
          Power User Veteran Regular Contributors
          wrote on last edited by
          #124

          Denny O NRP® standard panels are made with 100% PLAS-TEX® densified solid polymer. FRP PANELS are made from high quality gelcoat over cured mineral-filled polyester resin and random strand fiberglass matt.
          Simply put, it’s just a waterproof plastic wall panel.

          1 Reply Last reply
          2
          • DeepwoodsbutcherD Deepwoodsbutcher

            Denny O it’s nrp. It’s still USDA certified and was considerably cheaper then frp. I decided this was an area I could go with the money saving option.

            cdavisC Offline
            cdavisC Offline
            cdavis
            Team Blue Big Green Egg Masterbuilt Canning Kamado Joes Regular Contributors Power User
            wrote on last edited by
            #125

            Deepwoodsbutcher getting closer. Congrats to you 👏

            1 Reply Last reply
            1
            • DeepwoodsbutcherD Offline
              DeepwoodsbutcherD Offline
              Deepwoodsbutcher
              Power User Veteran Regular Contributors
              wrote on last edited by
              #126

              It’s been way too hot for me the past couple of days, but I managed to get one of the cooler doors covered and trimmed today. Had some help from my father in law and it turned out looking almost professional.
              20220616_151749.jpg
              20220616_151804.jpg
              20220616_151812.jpg

              C 1 Reply Last reply
              7
              • DeepwoodsbutcherD Offline
                DeepwoodsbutcherD Offline
                Deepwoodsbutcher
                Power User Veteran Regular Contributors
                wrote on last edited by
                #127

                My husband also got the outlets wired the other day
                20220613_193621.jpg

                kyleK C 2 Replies Last reply
                3
                • DeepwoodsbutcherD Deepwoodsbutcher

                  My husband also got the outlets wired the other day
                  20220613_193621.jpg

                  kyleK Offline
                  kyleK Offline
                  kyle
                  Regular Contributors Veteran Canning Team Blue Power User Sous Vide
                  wrote on last edited by
                  #128

                  Deepwoodsbutcher any progress is good progress. Thanks for the update

                  hey vegetarians, my food poops on your food!

                  1 Reply Last reply
                  1
                  • DeepwoodsbutcherD Deepwoodsbutcher

                    It’s been way too hot for me the past couple of days, but I managed to get one of the cooler doors covered and trimmed today. Had some help from my father in law and it turned out looking almost professional.
                    20220616_151749.jpg
                    20220616_151804.jpg
                    20220616_151812.jpg

                    C Offline
                    C Offline
                    calldoctoday
                    Team Blue Power User Regular Contributors
                    wrote on last edited by
                    #129

                    Deepwoodsbutcher Good move with the FRP, Marlite panels!

                    1 Reply Last reply
                    0
                    • DeepwoodsbutcherD Deepwoodsbutcher

                      My husband also got the outlets wired the other day
                      20220613_193621.jpg

                      C Offline
                      C Offline
                      calldoctoday
                      Team Blue Power User Regular Contributors
                      wrote on last edited by
                      #130

                      Deepwoodsbutcher I would make sure they are all GFI protected in the shop.

                      DeepwoodsbutcherD 1 Reply Last reply
                      2
                      • C calldoctoday

                        Deepwoodsbutcher I would make sure they are all GFI protected in the shop.

                        DeepwoodsbutcherD Offline
                        DeepwoodsbutcherD Offline
                        Deepwoodsbutcher
                        Power User Veteran Regular Contributors
                        wrote on last edited by
                        #131

                        calldoctoday fair point. They will all be enclosed in waterproof/ outdoor covers and not exposed. They are also placed well above table tops. There is also no running water in the shop. Water will be brought in by the bucket and hot cleaning will be done with a steamer. We made need to make that change sometime, especially if/ when I add running water. We did leave plenty of wire for down the road. Not everything will be ideal right away for sure. For now I’ll have to exercise caution in some areas, including this one.

                        C B 2 Replies Last reply
                        1
                        • G Offline
                          G Offline
                          glen
                          Regular Contributors Team Grey Sous Vide Canning Dry Cured Sausage Masterbuilt Power User Meat Hack Winner Veteran
                          wrote on last edited by
                          #132

                          You can use GFI breakers in your breaker box. The downside would be that in case of a fault detection every outlet on that circuit would drop

                          Give a man a fish and he eats for a day
                          Teach a man to fish and he drinks beer for a lifetime

                          1 Reply Last reply
                          2
                          • processheadP Offline
                            processheadP Offline
                            processhead
                            Regular Contributors Power User
                            wrote on last edited by processhead
                            #133

                            When wired in correctly, you need only one GFCI receptacle on each circuit. All the other regular receptacles are then protected by the first GFCI. It makes it much less work to bring everything up to code.

                            GFCI receptacles are also cheaper than GFCI breakers.

                            eac968ee-34be-4ce3-9c69-3e35c9ffd90c-image.png

                            Paul

                            C DeepwoodsbutcherD 2 Replies Last reply
                            6
                            • DeepwoodsbutcherD Deepwoodsbutcher

                              calldoctoday fair point. They will all be enclosed in waterproof/ outdoor covers and not exposed. They are also placed well above table tops. There is also no running water in the shop. Water will be brought in by the bucket and hot cleaning will be done with a steamer. We made need to make that change sometime, especially if/ when I add running water. We did leave plenty of wire for down the road. Not everything will be ideal right away for sure. For now I’ll have to exercise caution in some areas, including this one.

                              C Offline
                              C Offline
                              calldoctoday
                              Team Blue Power User Regular Contributors
                              wrote on last edited by
                              #134

                              Deepwoodsbutcher So long as you are comfortable with it, but I would add them. As glen duly noted too, the protection can be provided via multiple sources, including a GFCI breaker in the sub panel. If all the countertop type receptacles or outlets that you might be plugging into regularly & unplugging, along with any exterior or near any wash basins are on individual circuits & not too many, circuit breaker protection for the entire circuit would work best at this point & many.

                              1 Reply Last reply
                              1
                              • processheadP processhead

                                When wired in correctly, you need only one GFCI receptacle on each circuit. All the other regular receptacles are then protected by the first GFCI. It makes it much less work to bring everything up to code.

                                GFCI receptacles are also cheaper than GFCI breakers.

                                eac968ee-34be-4ce3-9c69-3e35c9ffd90c-image.png

                                C Offline
                                C Offline
                                calldoctoday
                                Team Blue Power User Regular Contributors
                                wrote on last edited by
                                #135

                                processhead So long as it is done right & they are all piggy backed to that first one on the load side downhill, as you probably were aware, since you mentioned it. Just wanted to make sure all involved understood what you were referring to.

                                processheadP 1 Reply Last reply
                                1
                                • C calldoctoday

                                  processhead So long as it is done right & they are all piggy backed to that first one on the load side downhill, as you probably were aware, since you mentioned it. Just wanted to make sure all involved understood what you were referring to.

                                  processheadP Offline
                                  processheadP Offline
                                  processhead
                                  Regular Contributors Power User
                                  wrote on last edited by
                                  #136

                                  calldoctoday said in Home meat processing shop:

                                  processhead So long as it is done right & they are all piggy backed to that first one on the load side downhill, as you probably were aware, since you mentioned it. Just wanted to make sure all involved understood what you were referring to.

                                  Correct. I added a diagram above that illustrates how the down stream outlets are fed from the GFCI outlet, which in turn is fed by the circuit breaker.

                                  Paul

                                  C 1 Reply Last reply
                                  2
                                  • processheadP processhead

                                    calldoctoday said in Home meat processing shop:

                                    processhead So long as it is done right & they are all piggy backed to that first one on the load side downhill, as you probably were aware, since you mentioned it. Just wanted to make sure all involved understood what you were referring to.

                                    Correct. I added a diagram above that illustrates how the down stream outlets are fed from the GFCI outlet, which in turn is fed by the circuit breaker.

                                    C Offline
                                    C Offline
                                    calldoctoday
                                    Team Blue Power User Regular Contributors
                                    wrote on last edited by
                                    #137

                                    processhead Good Job! Pardon me for being so quick on everything. I am supposed to be working, writing this report & behind as we had phones & internet down here for a hard day & a half, with internet sketchy. You did a much better job with your diagram than me trying to explain it general real quick.

                                    1 Reply Last reply
                                    2
                                    • DeepwoodsbutcherD Deepwoodsbutcher

                                      calldoctoday fair point. They will all be enclosed in waterproof/ outdoor covers and not exposed. They are also placed well above table tops. There is also no running water in the shop. Water will be brought in by the bucket and hot cleaning will be done with a steamer. We made need to make that change sometime, especially if/ when I add running water. We did leave plenty of wire for down the road. Not everything will be ideal right away for sure. For now I’ll have to exercise caution in some areas, including this one.

                                      B Offline
                                      B Offline
                                      bocephus
                                      Team Orange Power User Canning Masterbuilt Veteran
                                      wrote on last edited by
                                      #138

                                      Deepwoodsbutcher I think you should still put in GFIs, even without running water, you will still use water for cleaning.

                                      processheadP Denny OD 2 Replies Last reply
                                      2
                                      • processheadP processhead

                                        When wired in correctly, you need only one GFCI receptacle on each circuit. All the other regular receptacles are then protected by the first GFCI. It makes it much less work to bring everything up to code.

                                        GFCI receptacles are also cheaper than GFCI breakers.

                                        eac968ee-34be-4ce3-9c69-3e35c9ffd90c-image.png

                                        DeepwoodsbutcherD Offline
                                        DeepwoodsbutcherD Offline
                                        Deepwoodsbutcher
                                        Power User Veteran Regular Contributors
                                        wrote on last edited by
                                        #139

                                        processhead thank you for this! Seems like an easy enough solution. I’m sure my husband can make that change. We are definitely not electricians lol. This is what makes this site so great. A lot of different experience and knowledge. Thank you all for the ideas! I definitely want things to be safe.

                                        zbigjeffZ C 2 Replies Last reply
                                        3
                                        • B bocephus

                                          Deepwoodsbutcher I think you should still put in GFIs, even without running water, you will still use water for cleaning.

                                          processheadP Offline
                                          processheadP Offline
                                          processhead
                                          Regular Contributors Power User
                                          wrote on last edited by
                                          #140

                                          bocephus said in Home meat processing shop:

                                          Deepwoodsbutcher I think you should still put in GFIs, even without running water, you will still use water for cleaning.

                                          The code doesn’t only require GFCI protection for areas with running water. All kitchen counter receptacles are required to have them whether close to a sink or not.
                                          As little expense and labor as it would take to add them, I would agree that they are a good idea.

                                          Paul

                                          C DeepwoodsbutcherD 2 Replies Last reply
                                          2

                                          Hello! It looks like you're interested in this conversation, but you don't have an account yet.

                                          Getting fed up of having to scroll through the same posts each visit? When you register for an account, you'll always come back to exactly where you were before, and choose to be notified of new replies (either via email, or push notification). You'll also be able to save bookmarks and upvote posts to show your appreciation to other community members.

                                          With your input, this post could be even better 💗

                                          Register Login
                                          Reply
                                          • Reply as topic
                                          Log in to reply
                                          • Oldest to Newest
                                          • Newest to Oldest
                                          • Most Votes


                                          Sponsored By:

                                          Sponsored By Walton's Inc

                                          Sponsored By:

                                          Sponsored By Walton's
                                          Terms of Use - Privacy Policy - Copyright © 2023 Walton's Inc.
                                          Meatgistics
                                          X

                                          Register Now For Complete Access To Meatgistics!

                                          Sign In Register
                                          • Login

                                          • Don't have an account? Register

                                          • Login or register to search.
                                          • First post
                                            Last post
                                          0
                                          • Home
                                          • Walton's
                                            • Home
                                            • Seasonings
                                            • Casings
                                            • Packaging
                                            • Supplies
                                            • Equipment
                                            • Smoking/Grilling
                                            • Sales
                                            • Giveaways
                                          • About Us
                                          • Topics
                                            • Unread
                                            • Recent
                                            • Random
                                            • Popular Monthly
                                            • Popular All-Time
                                            • Unsolved
                                            • Solved
                                          • Events
                                          • FAQ
                                          • Conv Chart
                                            • Seasonings
                                            • Cures
                                            • Additives